How to check and maintain the worm gear reducer after use:
XNUMX. For the reducer with oil level plug
Check the oil level, whether it is qualified; install the oil level plug.
XNUMX. Oil replacement
After cooling, the viscosity of the oil increases and it is difficult to drain the oil. The reducer should change the oil at the operating temperature.Cut off the power to prevent electric shock!Wait for the reducer to cool down and there is no danger of burning!
Three, matters needing attention
Inject new oil of the same brand; the amount of oil should be the same as the installation position; check the oil level at the oil level plug; tighten the oil level plug and breather; the reducer should still be warm when changing the oil; Place an oil pan below; open the oil level plug, breather and oil drain plug; drain all the oil; install the oil drain plug.
Fourth, check the oil level
Cut off the power to prevent electric shock!Wait for the reducer to cool down; remove the oil level plug to check if the oil is full; install the oil level plug.