XNUMX. For the reducer with oil level plug, check the oil level to see if it is qualified; install the oil level plug.
XNUMX. Oil replacement. After cooling, the viscosity of the oil increases and it is difficult to drain the oil. The reducer should change the oil at the operating temperature.Cut off the power to prevent electric shock!Wait for the reducer to cool down and there is no danger of burning!
XNUMX. Precautions: inject new oil of the same brand; the oil quantity should be consistent with the installation position; check the oil level at the oil level plug; tighten the oil level plug and breather; the reducer should still be warm when changing the oil; Place an oil pan under the oil drain plug; open the oil level plug, breather and oil drain plug; drain all the oil; install the oil drain plug.
Fourth, check the oil level and oil inspection, cut off the power supply to prevent electric shock!Wait for the reducer to cool down; remove the oil level plug to check if the oil is full; install the oil level plug.The same is true for oil inspection. The first half is to open the oil drain plug and take an oil sample; check the viscosity index of the oil; if the oil is obviously turbid, it is recommended to replace it as soon as possible.